MAIN PAGE  |  ABOUT US  |  SYNDIS  |  PRODUCTS  |  TRAININGS  |  PARTNERS  |  NEWS  |  SERVICE  |  CONTACT  |  PRIVACY POLICY    PL  |  EN  |  RU  |  DE   
Systems
SYNDIS RV
Dedicated systems
Devices
Servers and workstations
Substation automation
Disturbance recorders
Digital substation
Power quality analysers
Automation devices in MV networks
Control-measuring automation
Monitoring
AMR/AMI
Data transmission
Data visualization
For smart building
Power supplying
Components
'MS' system modules (wide bus)
SO-52v11 family modules
SO-52v21 family modules
Controllers
Connection equipment
Specialized devices
SO-51 family modules
Applications
Area system with permission distribution
Substation system
SYNDIS ESB block transformer monitoring system
SYNDIS PQ power quality assessment system in a distribution company area
Controller RTU SO-52v21
Realization of automation functions in MV networks
Wind farms
SYNDIS RV AQUA
ARGUS RV-C
Components > SO-51 family modules []

The SO-51 bay controller is designed for direct, centralized control of any fields in the highest and medium voltage stations.
The SO-51 field controller is a ready device, equipped with all the elements needed for remote, local or manual control of the field in normal, backup or test mode. The controller is mounted in control cabinets.

...text in preparation


 WEJ-061 (binary inputs) []
 WEJ-065 (testing module) []
 WEJ-066 (testing module) []
 WEJ-068 (testing module) []
 WEJ-168 (testing module) []
 WYJ-074 (binary outputs) []
 ZWS-021 (control output protection module) []


WEJ-061 (binary inputs) []

The WEJ-061 package ensures permanent current protection of the object signaling circuits. The package has 16 inputs 220V/5mA DC.

...text in preparation


Exemplary WEJ-061

 


WEJ-065 (testing module) []

The WEJ-065 package is intended for testing the operation of WEJ-061 packets. It has 4 channels for testing up to four independent signaling circuits.

...text in preparation


Exemplary WEJ-065

 


WEJ-066 (testing module) []

The WEJ-066 package is intended for testing the operation of WEJ-061 packets. Twice a day, the program switches on the relays for 20 ms giving all inputs of the WEJ-061 packet voltage +220V, then 0V and reads the input states. Erroneous states are signaled to the center.

...text in preparation

 


WEJ-068 (testing module) []

The WEJ-068 package is intended for testing the operation of WEJ-061 packets. Twice a day, the program switches on the relays for 20 ms giving all inputs of the WEJ-061 packet voltage +220V, then 0V and reads the input states. Erroneous states are signaled to the center.

...text in preparation


Exemplary WEJ-068

 


WEJ-168 (testing module) []

The WEJ-168 package is a modernized version of the WEJ-068 package and is intended for testing WEJ-061 packages. Twice a day, the program switches on the relays for 20 ms giving all inputs of the WEJ-061 packet voltage +220V, then 0V and reads the input states. Erroneous states are signaled to the center.

...text in preparation


Exemplary WEJ-168

 


WYJ-074 (binary outputs) []

The WYJ-074 package is the object-oriented control interface. Allows remote activation/blocking of all packet relays simultaneously. It has 8 outputs with the following parameters: maximum conductivity 220V/2A DC, maximum switch-off current 220V/0,2A, each output is represented by two series-connected normally closed contacts and additionally the main relay contacts - high-current ones.

...text in preparation


Exemplary WYJ-074

 


ZWS-021 (control output protection module) []

The ZWS-021 packet controls the correctness of the output matrix switching via analog path, gives 24V DC voltage to the object relays acting on the WYJ packages. The connection of ZWS-021 packets with the PWY-201 and PEW-401 packets takes place through the contacts of the ADP-002 and ADP-006 adapters.

...text in preparation


Exemplary ZWS-021
 
   Print    Send e-mail to us